碩士生: 高瑋駿
畢業年月: 2017年6月
論文名稱: 太陽能板結合熱泵複合式系統之性能分析與優化 / Performance Analysis and Optimization of Solar Thermal and Heat Pump Combi-system
中文摘要:
本研究探討太陽能集熱器結合空氣源熱泵的生活熱水複合式系統。在台南建置並監測實驗室規模系統,可操作於太陽能熱水、熱泵熱水及兩者結合三種模式,並以實驗數據驗證TRNSYS模型。接著在相同負載下,於台北(亞熱帶)與高雄(熱帶)比較傳統太陽能熱水、單桶與雙桶複合式系統,結果顯示雙桶系統耗電與操作成本最低,並評估成本回收年限。最後以田口法在台南、里斯本、香港、大阪與馬德里五地優化系統,發現各因子影響程度隨地區與系統而異,但最顯著的因子在各地區一致。
英文摘要:
This thesis studies solar collector and air-source heat pump combisystems for domestic hot water. A lab-scale system installed and monitored in Tainan can run as a solar hot water, heat pump, or combined system, and a TRNSYS model is validated against the experimental data. Conventional solar hot water, single-tank, and dual-tank combisystems are then simulated under identical loads in Taipei (subtropical) and Kaohsiung (tropical); the dual-tank system has the lowest electricity use and operating cost, and payback periods are estimated. The Taguchi method then optimizes the systems for five climates (Tainan, Lisbon, Hong Kong, Osaka, Madrid), showing that parameter effects vary by region and system although the most significant parameter is consistent across regions.